Pneumatic Cylinder Force Calculator
Theoretical push and pull force for a single-rod pneumatic cylinder, with piston, rod and annular areas.
Cylinder force
How pneumatic cylinder force is calculated
Force is pressure multiplied by the area it acts on. For a cylinder, that area is the piston face when extending and the piston face minus the rod when retracting.
Piston area A_p = π × D² / 4 Rod area A_r = π × d² / 4 Annular area A_a = A_p − A_r Extension (push) F = P × A_p Retraction (pull) F = P × A_a Imperial: psi × in² = lbf Metric: bar × 0.1 = N/mm²; N/mm² × mm² = N; N ÷ 1000 = kN
D = bore diameter, d = rod diameter, P = gauge pressure at the cylinder.
Push vs pull force
Push (extension) force uses the full piston area. Pull (retraction) force uses the annular area around the rod. On a typical single-rod double-acting cylinder the rod reduces the effective area on the retract side, so pull force is always lower than push force at the same pressure. The larger the rod relative to the bore, the bigger the difference.
Theoretical vs actual force
This calculator does not subtract any allowance. Real available force is lower because of:
- Seal friction and mechanical friction
- Pressure losses in piping, fittings and filters
- Valve and tubing restrictions, especially at speed
- Back pressure on the exhaust side
- Operating conditions such as temperature, load angle and side loading
How pressure affects force
Force is directly proportional to pressure: 20% less pressure at the cylinder gives 20% less force.
How bore diameter affects force
Area increases with the square of the diameter. Going from a 2 in to a 4 in bore gives four times the area and four times the force at the same pressure — and uses roughly four times the air per stroke.
Force alone doesn't make a design safe
A force result says nothing about rod buckling, cushioning, kinetic energy at end of stroke, mounting strength, side loads, speed, or what happens when air pressure is lost or a valve fails. Use this as one input alongside manufacturer specifications, applicable standards and qualified engineering review.
Worked example (metric)
50 mm bore, 20 mm rod, 6 bar:
A_p = π × 50² / 4 = 1963.5 mm² A_r = π × 20² / 4 = 314.2 mm² A_a = 1963.5 − 314.2 = 1649.3 mm² P = 6 bar × 0.1 = 0.6 N/mm² Extension = 0.6 × 1963.5 ≈ 1178 N (1.18 kN) Retraction = 0.6 × 1649.3 ≈ 990 N (0.99 kN)
FAQ
Why is pull force lower than push force?
On a single-rod double-acting cylinder the rod occupies part of the piston face on the rod side. Pressure acts on the smaller annular area when retracting, so the same pressure produces less force.
Should I use gauge or absolute pressure?
Use gauge pressure. Cylinder force comes from the pressure difference across the piston, and with the opposite side vented to atmosphere that difference is the gauge pressure.
Is the calculated force what my cylinder will actually deliver?
No. The result is theoretical. Seal and mechanical friction, pressure losses, valve and tubing restrictions and back pressure all reduce available force. Check the manufacturer's data and allow margin.
What pressure should I enter?
Enter the pressure that actually reaches the cylinder while it is moving, not just the compressor or regulator setting. Pressure often drops through piping, fittings and valves.
Does doubling the bore double the force?
No — it roughly quadruples it. Area grows with the square of the diameter, so force does too.
Related calculators
Cylinder Calculator
Extension and retraction force from bore, rod and pressure.
Cylinder Bore Size
Size a bore for a required force at a given pressure.
Cylinder Air Consumption
Free air used per stroke, per cycle and per minute.
See how we handle units and assumptions on the methodology page.